CellarPro Wine Cellar Cooling Repair in Houston
We repair CellarPro cellar cooling units across Greater Houston, from the 1800 series to the VS, Houdini and split systems. We also work on the older units that were installed years before the high-efficiency models arrived.
Common CellarPro problems we fix
In plain words, the way owners describe them when they call.
Unit never stops running
HA alarm on the display
HA2 alarm and compressor off
Water leaking near the unit
Ice on the evaporator
P1 alarm and a timed on-off cycle
Screen locked and unit will not start
The CellarPro units we see in Houston
Most of our CellarPro calls involve the 1800 series, which includes the 1800, 1800QT, 1800XT, 1800XTS, 1800XTSr and the outdoor-rated 1800XTSx, plus the newer high-efficiency versions marked HE. The Houdini series (1800H and 3400H) manages condensate on its own, and the VS series comes in indoor and outdoor models such as the 2000VS, 3200VS, 4200VS, 6200VS and 8200VS. We also repair the VE series, split systems from the 3000S to the 8000S, the ceiling-mount versions and the AH air handlers and unit coolers.
These units are designed for a limited range of surrounding air, and a Houston garage or utility room in July can push past it. Dirty condenser coils and a clogged air filter make it worse, and the usual result is an HA or HA2 alarm, with the compressor shutting down until the condenser cools. Humidity brings condensate, so a drain line that is no longer clear is a common reason for water on the floor.
How we approach a CellarPro call
We read the alarm first. P1 means the cellar air probe has failed, and the unit then falls back to a timed on-and-off cycle that keeps cooling but not accurately. HA means the cellar has stayed warm, LA means it has gotten too cold, and PoF means the controller is locked. Then we look at the coils, filter, door seal and airflow.
On older units we confirm the full model number before ordering parts and say plainly when replacing is the better value. We write the price down before work starts, and every repair has a 30-day workmanship warranty.
CellarPro codes and alarms
What the display or the blinking light means, what is safe to check, and when to stop and call us.
CellarPro lines and model numbers we service
Current and older lines. Find the number on the model label and open its series for the usual repairs.
18001800QT1800XT1800XTS1800XTSr1800XTSx1800QT-HE1800XT-HE+5 more→CellarPro Air Handlers and Unit Coolers for Split SystemsCurrent and olderAH3500SxAH3500SiAH3500SChAH3500SCvAH4000SAH4000ShAH4000ScmrAH3000Scmr+18 more→CellarPro Houdini Self-Contained Cellar Cooling UnitsCurrent and older1800H1800H-HE1800H-220V3400H→CellarPro Split Cooling and Ceiling-Mount SystemsCurrent and older3000S4000S6000S8000S3000Sh4000Sh4000Shwc3000Sqc+12 more→CellarPro VE Series Self-Contained Cellar Cooling UnitsCurrent line3200VEi3200VEx4200VEi4200VEx→CellarPro VS Series Indoor and Outdoor Self-Contained UnitsCurrent and older2000VS2000VSi-HE2000VSx-HE2000VSi-220V2000VSx-220V3200VS3200VSi3200VSx+11 more→My CellarPro unit never shuts off. Is that normal?
Constant operation usually comes from a hot space around the unit, a door or seal that leaks, or a set point that is very low. We check airflow and the cellar envelope first, then the controls.
What does a P1 alarm on a CellarPro mean?
P1 is the cellar air probe alarm. The unit keeps going in a timed cycle, twelve minutes on and eight off, until the probe is replaced. Call us and we will test the probe and its connection.
Do you repair the older CellarPro units, not just the HE models?
Yes. Older 1800 series and split units are still cooling cellars in Houston. We repair them, confirm parts by model number and tell you when replacement is the better choice.